Showing posts with label v430. Show all posts
Showing posts with label v430. Show all posts

Tuesday, March 22, 2022

Solved: Omron Microscan WebLink connection failure is caused by avoidable settings

Do NOT set the Omron V430 reader "End Cycle On" to "New Trigger" if its "Trigger mode" is "Continuous".  Set the "End Cycle On" to "Timeout or New Trigger".  

Without the timeout option the CPU does not get a chance to accept the WebLink connection.

Here is a video that show the solution:


https://youtu.be/-Bwe_9T4Ojk


Friday, February 11, 2022

Omron Microscan V430 slow or no connection, a work-around

 I was stumped on why the web page would not come up.  

It goes without saying, check the IP address and subnet mask.

The default IP of the Omron Microscan V430 is   192.168.188.2  subnet mask 255.255.0.0

I could ping it.  I could Telnet into it.  But the webpage wouldn't connect.

Answer: Cover the lens. 

WHAT?  How does covering the lens fix a connection problem?

The camera was in continuous acquisition.  It was spending all of its CPU time on finding and decoding a barcode.  There was no time left to allow connection requests.

Covering up the lens blanks the image.  The barcode search fails immediately, allowing the CPU to perform other tasks.